Solenoid operated piston pump EX
Specifications Pump Discharge Volume 0.4〜0.9ml/stroke (Adjustable) Discharge Pressure 0.4MPaMax Voltage / Current AC100Vφ1 AC200Vφ1 (50Hz/60Hz) Oil level switch (Option) Solenoid Voltage AC100V 50Hz Retention 0.5A Start-up 5.8A 60Hz Retention 0.52A Start-up 6.0A AC200V 50Hz Retention 0.25A Start-up 2.9A 60Hz Retention 0.26A Start-up 3.0A Working Viscosity Range 32〜1300mm2/S Reservoir Capacity 1.8l Weight 1.85kg How To Order Model Model Part Number EX-1 […]
Detail infor
Specifications
Pump | Discharge Volume | 0.4〜0.9ml/stroke (Adjustable) | |
---|---|---|---|
Discharge Pressure | 0.4MPaMax | ||
Voltage / Current | AC100Vφ1 AC200Vφ1 (50Hz/60Hz) | ||
Oil level switch (Option) |
Solenoid Voltage | AC100V | 50Hz Retention 0.5A Start-up 5.8A |
60Hz Retention 0.52A Start-up 6.0A | |||
AC200V | 50Hz Retention 0.25A Start-up 2.9A | ||
60Hz Retention 0.26A Start-up 3.0A | |||
Working Viscosity Range | 32〜1300mm2/S | ||
Reservoir Capacity | 1.8l | ||
Weight | 1.85kg |
How To Order
Model
Model | Part Number |
---|---|
EX-1 | 102703 |
EX-1C | 102701 |
EX-1LC | 102705 |
Model | Part Number |
---|---|
EX-2 | 102702 |
EX-2C | 102700 |
EX-2LC | 102704 |
Directions for use
● | Oil viscosity varies with oil temperature. Be sure to use oil within the working viscosity range. Refer to the viscosity table. |
● | Do not use any special additive-contained oil, water soluble oil and solvent. |
● | Periodically check the oil in the reservoir for impurities. Replace it, if necessary, with fresh oil immediately. Be sure to clean the reservoir before oil change. |
● | Make sure that proper voltage and pressure are proper. |
● | Do not overtighten the discharge joint. Refer to the tightening torque table. |
● | Do not operate the pump dry. |
Oil quantity adjustment method
-
① reduce the coupling rod hexagonal portion, please loosen up the ③ lock nut 2 spring washer become free.
After setting the rotation desired discharge? Amounts ④ adjustment screw in the direction indicated by the solid arrow If you want to increase the amount, fixed by the ② and ③.
If you want to reduce the amount, after setting the desired discharge amount to rotate the ④ adjustment screw in the dotted arrow direction, it is fixed by the ② and ③.
Adjustment screw is the adjustment amount in one rotation is 0.06ml.
Document
Pump Drawing
Wiring digram
Dimensional Drawing
Improper handling can result in a death or serious injury. | |
Electrical shock may be received under certain conditions.。 | |
Be sure to ground. |